FN2200B-50-34

50 A EMV Filter mit Klemmenanschluss

Most important files and data about the article you can take over here.

Downloads

General Information

Designation

FN2200B-50-34

SAP Number

803513
FN2200

Description

50 A EMV Filter mit Klemmenanschluss

Type

Chassis mount

Phases

Gleichstrom
Distribution stock
General
Voltage AC (V) 1200
Nominal Frequency (Hz) DC
Rated Current @ambient (A) 50
Ambient temperature (°C) 55
Electric
Input terminal 34 - STB25 25mm2
Output terminal 34 - STB25 25mm2
Power Loss (W) 17
Attenuation
DM attenuation @ 150kHz (dB) 35
Mechanic
Length (mm) 170
Width (mm) 95
Height (mm) 80
Volume (cm3) 1292
Weight (g) 1650

Schaffner schemes

Mechanical Data Image

Dimensions
A (mm) 200
B (mm) 95
C (mm) 80
D (mm) 170
E (mm) 182.5
F (mm) 60,75
G (mm) 5.5
H (mm) 1.5
I (mm) 39
J (mm) M6