FN280FN280

Power Entry Module with EMC- Filter FN280

Compact filtered power entry module

FN280

Compact filtered power entry module

  • Complies with IEC/EN 60601-1
  • Rated currents up to 10 A
  • Single or dual-fuse holder
  • Fuses ø5 x 20 mm
  • 2-pole rocker switch
  • General purpose application
  • Optional earth line choke (E type)
  • Optional medical versions (B type)

Articles

Article Rated Current @ambient Input/Output connections (Nm) Distribution stock Compare Read More
Input terminal Output terminal
FN284EB-6-06 FN284EB-6-06 627 - IEC-plug06 - faston 6.3x0.8/sold lug

Features and Benefits

High conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior
Rear/front or snap-in mounting
Single or dual-fuse holder
2-pole rocker switch
Custom-specific versions are available on request

Typical Applications

Portable electrical and electronic equipment
Consumer goods
EDP and office equipment
Single-phase power supplies, switch-mode power supplies
Test and measurement equipment
Medical equipment

Technical Specifications

Maximum continuous operating voltage

250 VAC, 50/60 Hz

Nominal operating voltage

230 VAC

Rated currents

1 to 10 A @ 40°C

Operating frequency

DC to 400 Hz

High potential test voltage

P –> PE 2000 VAC for 2 sec (standard types)

P –> PE 2500 VAC for 2 sec (B types)

P –> N 760 VAC for 2 sec

Temperature range (operation and storage)

-25°C to +85°C (25/85/21)

Protection category

IP 40 according to IEC 60529

Flammability corresponding to

UL 94 V-2 or better

Design corresponding to

UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939

MTBF (Mil-HB-217F)

>1,500,000 h @ 40°C/230 V

Fuse holder

1 or 2 fuses (Ø5 x 20 mm) (certified to IEC 60127-6), power acceptance 1.6W @ Ta 23°C per pole for 2 fuses. 2.5W, if only 1 pole is used.

Marking

Marking max. 250 V ~ (text is print. below fuse symbol)

Rocker switch description

&nbsp

Switch ratings

&nbsp

Function

2-pole, dark not illuminated

Marking I - 0

Electrical specifications

Inrush current 82 A

6,000 on-off operations according to UL 1054, TV5

10,000 on-off operations according to ENEC

Europe (ENEC)

10 A (4 A), 250 VAC*

USA (UL) and Canada (C-UL)

10 A, 125 VAC

10 A, 250 VAC

1/3 HP

* Value in () relates to the inductive current charge: cos(phi) = 0.65

Typical electrical schematic

FN280

Approvals & Compliances

UL Recognized Label
CSA Label
ENEC 14 Label
CQC Label
RoHS Label
CE Label
UKCA Label
KC Label

(CQC except HI-types)

Back