FN 3410 ECOsine™ 50Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3410HV ECOsine™ 50Hz Passive Harmonic Filters for 690V
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 7.5 to 250 kW
- Voltage: 690 V
FN 3411 ECOsine™ 50Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3411HV ECOsine™ 50Hz Passive Harmonic Filters for 690V
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 7.5 to 250 kW
- Voltage: 690 V
FN 3412 ECOsine™ 60Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 5 to 250 HP
- Voltage: 380 to 480 V
FN 3413 ECOsine™ 60Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 5 to 250 HP
- Voltage: 380 to 480 V
FN 3416 ECOsine™ Passive Harmonic Filters
- Economy line of passive harmonic
- filters for THID <10 %
- Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
- Support an efficient utilization of electrical system capacity
- Ideal for motor drives with 6-pulse rectifier front-end
- Same filter for both diode and thyristor (SCR) rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 10%
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3418 ECOsine™ Passive Harmonic Filters
- Economy line of passive harmonic filters for THID <10 %
- Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
- Support an efficient utilization of electrical system capacity
- Ideal for motor drives with 6-pulse rectifier front-end
- Same filter for both diode and thyristor (SCR) rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID < 10%
- Rated Power: 4 to 200 HP
- Voltage: 380 to 480 V
(30A to 100A UL recognized / 200A to 300A UL listed)
FN 3420 ECOsine™ Active Harmonic Filters (3-wire)
- Global or selective compensation of
- harmonic currents up to the 50th order
- Compensation of displacement power factor
- Load balancing capability
- Response time of less than 300 microseconds
- Compact solution for easy installation and intuitive operation
- Compensation current: 30 to 300 A
- Frequency: 47 to 63 Hz
- Harmonic mitigation: THID < 5%,THID adjustable
- Voltage: 200 to 480 V
FN 3430 ECOsine™ Active Harmonic Filters (4-wire)
- Global or selective compensation of harmonic currents up to the 50th order
- Compensation of displacement power factor
- Load balancing capability
- Response time of less than 300 microseconds
- Compact solution for easy installation and intuitive operation
- Compensation current: 30 to 300 A
- Frequency: 47 to 63 Hz
- Harmonic mitigation: THID < 5%,THID adjustable
- Voltage: 380 to 415 V
RWK 212 Three-phase line reactor for motor drive applications
- Reduction of mains harmonics
- Reduction of commutation notches
- Protection of motor drive electronics
- Limitation of inrush currents
- Improvement of true power factor
- Frequency: 50 to 60 Hz
- Harmonic mitigation: THID appr. 40%
- Impedance: 4 % @ 400 VAC, 50 Hz & rated current
- Motor power: 1.5 to 630 kW
- Rated Current: 4 to 1100 A
- Voltage: ≤ 500 V
Configurator
Categories
Downloads
- : Application Example ECOsine™ Acitve - Paper Industry
- : Application Example ECOsine™ Acitve - Water/Wastewater Treatment Facilities
- : Brochure ECOsine™ Active - 200V
- : Application Example ECOsine™ Active - KKL Lucerne (Culture and Conference Centre)
- : Application Example ECOsine™ Active - Road Tunnels
- : Application Example ECOsine™ Active - Supermarket
- : Application Example ECOsine™ Active - Tschuggen Express
- : User Manual ECOsine™ Active Harmonic Filters
- : Brochure ECOsine™ Active- Harmonics Compensation in Real-time
- : User Manual ECOsine™ – FN 3410_11 & FN 3412_13
- : User Manual ECOsine™ – FN 3416 & FN 3418
- : Datasheet ECOsine™ – FN 3416 & FN 3418
- : Brochure ECOsine™ – FN3410_11 & FN 3412_13
- : Installation Instructions Environmental conditions AHF
- : User Manual Filtres anti-harmoniques ECOsine™ Active (2e rév.,07/2009)
- : White Paper Proper Selection of Passive and Active Power Quality Filters
08.04.2013