Products: 11
FN 3410 ECOsine™ 50Hz Passive Harmonic Filters

FN 3410 ECOsine™ 50Hz Passive Harmonic Filters

  • The industry standard for 6-pulse rectifiers and motor drives
  • The most compact 5% THID filter available
  • Excellent behavior under partial load conditions
  • Filters for diode rectifiers
  • Frequency: 50 Hz
  • Harmonic mitigation: THID < 5%
  • Rated Power: 4 to 200 kW
  • Voltage: 380 to 500 V
  •  
  •  
  •  
  •  
FN 3410HV ECOsine™ 50Hz Passive Harmonic Filters for 690V

FN 3410HV ECOsine™ 50Hz Passive Harmonic Filters for 690V

  • The industry standard for 6-pulse rectifiers and motor drives
  • The most compact 5% THID filter available
  • Excellent behavior under partial load conditions
  • Filters for diode rectifiers
  • Frequency: 50 Hz
  • Harmonic mitigation: THID < 5%
  • Rated Power: 7.5 to 250 kW
  • Voltage: 690 V
  •  
  •  
  •  
  •  
FN 3411 ECOsine™ 50Hz Passive Harmonic Filters

FN 3411 ECOsine™ 50Hz Passive Harmonic Filters

  • The industry standard for 6-pulse rectifiers and motor drives
  • Excellent behavior under partial load conditions
  • Filters for thyristor (SCR) rectifiers
  • Frequency: 50 Hz
  • Harmonic mitigation: THID depending upon firing angle
  • Rated Power: 4 to 200 kW
  • Voltage: 380 to 500 V
  •  
  •  
  •  
  •  
FN 3411HV ECOsine™ 50Hz Passive Harmonic Filters for 690V

FN 3411HV ECOsine™ 50Hz Passive Harmonic Filters for 690V

  • The industry standard for 6-pulse rectifiers and motor drives
  • Excellent behavior under partial load conditions
  • Filters for thyristor (SCR) rectifiers
  • Frequency: 50 Hz
  • Harmonic mitigation: THID depending upon firing angle
  • Rated Power: 7.5 to 250 kW
  • Voltage: 690 V
  •  
  •  
  •  
  •  
FN 3412 ECOsine™ 60Hz Passive Harmonic Filters

FN 3412 ECOsine™ 60Hz Passive Harmonic Filters

  • The industry standard for 6-pulse rectifiers and motor drives
  • The most compact 5% THID filter available
  • Excellent behavior under partial load conditions
  • Filters for diode rectifiers
  • Frequency: 60 Hz
  • Harmonic mitigation: THID < 5%
  • Rated Power: 5 to 250 HP
  • Voltage: 380 to 480 V
  •  
  •  
  •  
  •  
FN 3413 ECOsine™ 60Hz Passive Harmonic Filters

FN 3413 ECOsine™ 60Hz Passive Harmonic Filters

  • The industry standard for 6-pulse rectifiers and motor drives
  • Excellent behavior under partial load conditions
  • Filters for thyristor (SCR) rectifiers
  • Frequency: 60 Hz
  • Harmonic mitigation: THID depending upon firing angle
  • Rated Power: 5 to 250 HP
  • Voltage: 380 to 480 V
  •  
  •  
  •  
  •  
FN 3416 ECOsine™ Passive Harmonic Filters

FN 3416 ECOsine™ Passive Harmonic Filters

  • Economy line of passive harmonic
  • filters for THID <10 %
  • Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
  • Support an efficient utilization of electrical system capacity
  • Ideal for motor drives with 6-pulse rectifier front-end
  • Same filter for both diode and thyristor (SCR) rectifiers
  • Frequency: 50 Hz
  • Harmonic mitigation: THID < 10%
  • Rated Power: 4 to 200 kW
  • Voltage: 380 to 500 V
  •  
  •  
  •  
  •  
FN 3418 ECOsine™ Passive Harmonic Filters

FN 3418 ECOsine™ Passive Harmonic Filters

  • Economy line of passive harmonic filters for THID <10 %
  • Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
  • Support an efficient utilization of electrical system capacity
  • Ideal for motor drives with 6-pulse rectifier front-end
  • Same filter for both diode and thyristor (SCR) rectifiers
  • Frequency: 60 Hz
  • Harmonic mitigation: THID < 10%
  • Rated Power: 4 to 200 HP
  • Voltage: 380 to 480 V
  •  
  •  
  •  
  •  
FN 3420 ECOsine™ Active Harmonic Filters (3-wire)
(30A to 100A UL recognized / 200A to 300A UL listed)

FN 3420 ECOsine™ Active Harmonic Filters (3-wire)

  • Global or selective compensation of
  • harmonic currents up to the 50th order
  • Compensation of displacement power factor
  • Load balancing capability
  • Response time of less than 300 microseconds
  • Compact solution for easy installation and intuitive operation
  • Compensation current: 30 to 300 A
  • Frequency: 47 to 63 Hz
  • Harmonic mitigation: THID < 5%,THID adjustable
  • Voltage: 200 to 480 V
  •  
  •  
  •  
  •  
FN 3430 ECOsine™ Active Harmonic Filters (4-wire)

FN 3430 ECOsine™ Active Harmonic Filters (4-wire)

  • Global or selective compensation of harmonic currents up to the 50th order
  • Compensation of displacement power factor
  • Load balancing capability
  • Response time of less than 300 microseconds
  • Compact solution for easy installation and intuitive operation
  • Compensation current: 30 to 300 A
  • Frequency: 47 to 63 Hz
  • Harmonic mitigation: THID < 5%,THID adjustable
  • Voltage: 380 to 415 V
  •  
  •  
  •  
  •  
RWK 212 Three-phase line reactor for motor drive applications

RWK 212 Three-phase line reactor for motor drive applications

  • Reduction of mains harmonics
  • Reduction of commutation notches
  • Protection of motor drive electronics
  • Limitation of inrush currents
  • Improvement of true power factor
  • Frequency: 50 to 60 Hz
  • Harmonic mitigation: THID appr. 40%
  • Impedance: 4 % @ 400 VAC, 50 Hz & rated current
  • Motor power: 1.5 to 630 kW
  • Rated Current: 4 to 1100 A
  • Voltage: ≤ 500 V
  •  
  •  
  •  
  •  
  •  
  •  

Configurator

 -   V
Choose Voltage

Categories

Downloads

08.04.2013

Power Cord with Locking System for IEC Inlets