FN 280 Compact filtered power entry module
(CQC except HI-types)

 

FN 280 Compact filtered power entry module

 

  • Complies with IEC/EN 60601-1
  • Rated currents up to 10 A
  • Single or dual-fuse holder
  • Fuses Ø 5 x 20 mm
  • 2-pole rocker switch
  • General purpose application
  • Optional earth line choke (E type)
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Frequency: 50 to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 370 Versatile Filtered Power Entry Module

 

FN 370 Versatile Filtered Power Entry Module

 

  • Rated currents up to 6 A
  • Single or dual-fuse holder
  • Fuses Ø 6.3 x 32 mm or Ø 5 x 20 mm
  • Voltage selector 100/120/230/240 V
  • General purpose application
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 2 to 6 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 380 Versatile filtered power entry module

 

FN 380 Versatile filtered power entry module

 

  • Rated currents up to 6 A
  • Single or dual-fuse holder
  • Fuses Ø 6.3 x 32 mm Ø 5 x 20 mm
  • 2-pole rocker switch
  • General purpose application
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 2 to 6 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 390 Versatile filtered power entry module

 

FN 390 Versatile filtered power entry module

 

  • Rated currents up to 10 A
  • For one or two fuses
  • Fuses Ø 6.3 x 32 mm or Ø 5 x 20 mm
  • 2-pole rocker switch
  • Voltage selector
  • Optional earth line choke (E type)
  • Attenuation performance: high
  • Leakage current: 560 to 797 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
FN 9222 General performance IEC inlet filter
(CQC except HI-types)

 

FN 9222 General performance IEC inlet filter

 

  • Rated currents up to 20 A
  • Excellent performance/size ratio
  • Optional medical versions (B type) according to IEC/EN 60601-1
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Optional overvoltage protection (Z type)
  • Attenuation performance: standard
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 20 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9222E General performance IEC inlet filter with earth line choke
(CQC except HI-types)

 

FN 9222E General performance IEC inlet filter with earth line choke

 

  • Rated currents up to 15 A
  • Excellent performance/size ratio
  • Integrated earth line choke
  • Complies with IEC/EN 60601-1
  • Snap-in versions (S and S1 type)
  • Optional wide mounting flanges
  • Attenuation performance: standard
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9226 HF performance IEC inlet filter

 

FN 9226 HF performance IEC inlet filter

 

  • Rated currents up to 10 A
  • Faston connection
  • Optional PCB through hole connection
  • Good HF coupling to the equipment housing
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 9233 High performance IEC inlet filter
(CQC except HI-types)

 

FN 9233 High performance IEC inlet filter

 

  • Rated currents up to 15 A
  • Excellent attenuation performance
  • Complies with IEC/EN 60601-1
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: standard, high
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9233E High performance IEC inlet filter with earth line choke
(CQC except HI-types)

 

FN 9233E High performance IEC inlet filter with earth line choke

 

  • Rated currents up to 15 A
  • Excellent attenuation performance
  • Integrated earth line choke
  • Complies with IEC/EN 60601-1
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: high, very high
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9244 Excellent Performance IEC Inlet Filter
(CQC except HI-types)

 

FN 9244 Excellent Performance IEC Inlet Filter

 

  • Superior attenuation performance
  • Optional earth line choke
  • Complies with IEC/EN 60601-1
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: very high
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9244E Excellent performance IEC inlet filter with earth line choke
(CQC except HI-types)

 

FN 9244E Excellent performance IEC inlet filter with earth line choke

 

  • Rated currents up to 15A
  • Superior attenuation performance
  • Integrated earth line choke
  • Complies with IEC/EN 60601-1
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: very high
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9246 High performance IEC inlet filter

 

FN 9246 High performance IEC inlet filter

 

  • Rated currents up to 20 A
  • Optional medical versions (B type)
  • Rear mounting
  • Excellant attenuation in the lower
  • frequency range
  • Attenuation performance: high
  • Leakage current: 373 to 797 µA
  • Leakage current (B types): 2 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 20 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 9260 General purpose power entry module with fuses

 

FN 9260 General purpose power entry module with fuses

 

  • Rated currents up to 10 A
  • For one or two fuses
  • Optional safety version (A type)
  • Complies with IEC/EN 60601-1
  • Snap-in versions (S type)
  • Attenuation performance: standard
  • Leakage current: 373 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
FN 9263 General Purpose Power Entry Module with Mains Switch
(CQC except HI-types)

 

FN 9263 General Purpose Power Entry Module with Mains Switch

 

  • Rated currents up to 10A
  • 1-pole rocker switch
  • Snap-in versions (S and S1 type)
  • Compact to fit 1U rack size
  • Attenuation performance: standard
  • Leakage current: 373 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
FN 9264 Compact power entry module
(CQC except HI-types)

 

FN 9264 Compact power entry module

 

  • Compact size
  • Rated currents up to 10 A
  • Complies with IEC/EN 60601-1
  • High quality 2-pole rocker switch
  • Good attenuation performance
  • Snap-in versions (S type)
  • Attenuation performance: high
  • Leakage current: 373 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
(CQC except HI-types); Patent US20110227692 / US8766761

 

FN 9280 Ultra Compact and Versatile Filtered Power Entry Module

 

  • Single stage filter
  • Ultra compact design
  • Rated currents up to 10 A
  • dual-fuse holder
  • Fuses Ø5x20mm
  • 2-pole rocker switch
  • Good attenuation performance
  • Faston or spring cage terminals
  • Attenuation performance: high
  • Leakage current medical (B types): < 5 µA
  • Leakage current standard: < 500 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
(CQC except HI-types); Patent US20110227692 / US8766761

 

FN 9290 Ultra Compact and Versatile Filtered Power Entry Module

 

  • Dual stage filter
  • Ultra compact design
  • Rated currents up to 10 A
  • Dual fuse holder
  • 2-pole rocker switch
  • Good attenuation performance
  • Faston or spring cage terminals
  • Attenuation performance: very high
  • Leakage current medical (B types): < 5 µA
  • Leakage current standard: < 500 µA
  • Operating frequency: dc to 400 Hz
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
Power cord with Locking System IL13, IL13P, IL19

 

Power cord with Locking System IL13, IL13P, IL19

 

  • Locking system for standardized IEC C14/C20 inlet filter
  • No accidental disconnection
  • Rated current up to 10 A (C13 plug) and up to 16 A (C19 plug)
  • Fits any Schaffner IEC C14/C20 inlet filter
  • Retrofit for any IEC C14/C20 inlet
  • Various power line plugs for international usage
  • Color: black
  • Connector line side: C14; CEE7/VII; BS1363; NEMA5-15; SEV1011; JIS8303
  • Connector load side: C13 with IEC lock
  • Frequency: 50/60 Hz
  • Length: 2 m
  • Operating frequency: dc to 60 Hz
  • Rated Current: 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
  •  
  •  

Configurator

 -   V
Choose Voltage
 -   A
Choose Current
 -   
Choose Attenuation performance

Categories

Downloads

20.10.2014

ECOsine ® Active – new harmonic filters with Germanischer Lloyd (GL)

EMC/EMI Glossary